RE Installation Manual
4-20
Copyright
2001 Phone: (614) 771-2718 RE-4500
Vanner Inc. FAX: 614-771-4904 Owners Manual
4282 Reynolds Dr. www.vanner.com Rev 01e
Hilliard Ohio 43026 RE-Installation_Manual_Rev01e 910157-A
INCORPORATED
INCORPORATEDINCORPORATED
INCORPORATED
e.
Choose the "End Chrg Type" to be "<DC
CURRENT." Press the Top Right Key.
f.
Next make the "End Chrg Set'g" "20.0 Adc" (
10 A
DC
for the RE48-4500
) or whatever ending current is
correct for your battery bank. Press the Top Right Key.
g.
And last, set "Charge Timeout" to "24.00 Hours."
Press ESC to go back up the menu.
During this final charging step, the inverter will hold the
battery bank at the voltage setting until the battery current
falls to less than the setting or until a day has gone by. The
inverter will then go back to the FIRST step, and start
over.
Example 2 – 7 Step Charging Cycle
This example is for the factory setting 7 step charging steps.
This 7 step charging cycle is a 7-stage bulk charge for flooded
lead acid batteries (similar to the Vanner Incorporated TruSine
TSC24-4500).
To change or review the setpoints, use the ICC remote to go up
to the charger menu and look at "Charging Stges." The
Charging Stages factory setting is 7 meaning there are 7 stages
or steps the inverter performs when charging the batteries. Hit
the MENU key to bring up the charging steps menu.
1.
Perform the first set of charging steps:
a.
Use the remote to set "Charge Step #" to 1. (The first
charging stage) Press the Top Right Key.
b.
"Charge Stage ," the charging stage name, is "STRT,"
obviously standing for "start". Press the Top Right
Key.
c.
The "Charge Type" is "DC CURRENT," or current
into or out of the battery. Press the Top Right Key.
d.
The "Charge Setting" is "0.0 Adc," meaning nothing
will happen. Press the Top Right Key.
e.
The "Trigger Type" is "<DC VOLTAGE," meaning
the inverter charger will leave the first charging stage
when the battery voltage is less than some number.
Press the Top Right Key.
f.
The "Trigger Settng" is "22.00 Vdc," (
44 V
DC
for the
RE48-4500
) the voltage you want the batteries to
Vue de la page 55