Charging Settings
SETTING NAME FACTORY VALUE DEFAULT VALUE
Charge Stage #1
Charge Stage Name "STRT" "STRT"
Charge Stage Type DC POWER DC CURRENT
Trigger Type < DC VOLTAGE < DC VOLTAGE
Charge Stage Setting -300 W 0.0 Adc
Trigger Setting 22.00 Vdc 22.00 Vdc
Charge Stage Timeout 0.00 Hours 0.00 Hours
Charge Stage #2
Charge Stage Name "BLKC" "BLKC"
Charge Stage Type DC CURRENT DC CURRENT
Trigger Type >= DC VOLTAGE >= DC VOLTAGE
Charge Stage Setting 100.0 Adc 100.0 Adc
Trigger Setting 28.40 Vdc 28.40 Vdc
Charge Stage Timeout 24.00 Hours 24.00 Hours
Charge Stage #3
Charge Stage Name "BLKV" "BLKV"
Charge Stage Type DC VOLTAGE DC VOLTAGE
Trigger Type < DC CURRENT < DC CURRENT
Charge Stage Setting 28.4 Vdc 28.4 Vdc
Trigger Setting 55.0 Adc 55.0 Adc
Charge Stage Timeout 1 Hour 1 Hour
Charge Stage #4
Charge Stage Name "ABRB" "ABRB"
Charge Stage Type DC CURRENT DC CURRENT
Trigger Type >= DC VOLTAGE >= DC VOLTAGE
Charge Stage Setting 50.0 Adc 50.0 Adc
Trigger Setting 30.00 Vdc 30.00 Vdc
Charge Stage Timeout 0.25 Hour 0.25 Hour
Charge Stage #5
Charge Stage Name "EQUL" "EQUL"
Charge Stage Type DC VOLTAGE DC VOLTAGE
Trigger Type < DC CURRENT < DC CURRENT
Charge Stage Setting 31.00 Vdc 31.00 Vdc
Trigger Setting 10.00 Adc 10.00 Adc
Charge Stage Timeout 0.25 Hour 0.25 Hour
Charge Stage #6
Charge Stage Name "FLTV" "FLTV"
Charge Stage Type DC VOLTAGE DC VOLTAGE
Trigger Type >= DC CURRENT >= DC CURRENT
Charge Stage Setting 26.40 Vdc 26.40 Vdc
Trigger Setting 50.00 Adc 50.00 Adc
Charge Stage Timeout 1 Hour 1 Hour